FRED310 | Frederickson, WA
  • Home
  • Park Overview
  • Download Brochure
  • Contact
Picture
Picture

PARK OVERVIEW

 Available Now 

Building G Specifications
Building G
Building SF 611,340
Available SF 611,340
Office SF 3,498
Site SF 1,285,020
Coverage 47.39%
Trailer Park 158
Auto Park 370
Trailer Court Depth 130’
Slab Thickness 8”
Building Dimensions 570 x 1046
Clear Height 40’
Single/Multi Tenant Multi
Fire Sprinkler ESFR
Electrical Power 3,000
Dock High Doors 106
Construction Completed June 2024

Phase 2

Building Comparison Table
Property Building A Building B
Building SF 320,040 398,188
Site SF 457,380 1,106,424
Coverage 42.98% 35.99%
Trailer Park 56 166
Auto Park 200 244
Trailer Court Depth 135’ 130’
Slab Thickness 6” 7”
Building Dimensions 355 x 896 294 x 1332
Clear Height 32’ 36’
Single/Multi Tenant Multi Multi
Fire Sprinkler ESFR ESFR
Electrical Power 2,000 2,000
Dock High Doors 48 74
Picture
Picture

BUILDING SPECIFICATIONS

Building G

Building Specifications Table
Building SF 611,340
Available SF 611,340
Office SF 3,498
Site SF 1,285,020
Coverage 47.39%
Trailer Park 158
Auto Park 370
Trailer Court Depth 130’
Slab Thickness 8”
Building Dimensions 570 x 1046
Clear Height 40’
Single/Multi Tenant Multi
Fire Sprinkler ESFR
Electrical Power 3,000
Dock High Doors 106
Drive-In Doors 4

SITE PLAN

Picture
Picture

Phase 2

BUILDING SPECIFICATIONS

Building A

Building Specifications Table
Building SF 320,040
Site SF 457,380
Coverage 42.98%
Trailer Park 52
Auto Park 200
Trailer Court Depth 135’
Slab Thickness 6”
Building Dimensions 355 x 896
Clear Height 32’
Single/Multi Tenant Multi
Fire Sprinkler ESFR
Electrical Power 2,000
Dock High Doors 48
Drive-In Doors 2

SITE PLAN

Picture
Picture

Phase 2

BUILDING SPECIFICATIONS

Building B

Building Specifications Table
Building SF 398,188
Site SF 1,106,424
Coverage 35.99%
Trailer Park 166
Auto Park 244
Trailer Court Depth 130’
Slab Thickness 7”
Building Dimensions 294 x 1332
Clear Height 36’
Single/Multi Tenant Multi
Fire Sprinkler ESFR
Electrical Power 2,000
Dock High Doors 74
Drive-In Doors 2

SITE PLAN

Picture

For More Information, Please Contact:

SCOTT ALAN, SIOR  |  Executive Managing Director  |  +1 206 521 0236  |  [email protected]
PATRICK MULLIN  |  Executive Managing Director  |  +1 206 521 0265  |  [email protected]​
CONNOR CREE  |  Executive Director  |  +1 206 521 0289  |  [email protected]
ANDREW SHULTZ  |  Senior Director  |  +1 206 215 1645  |  [email protected]
Site powered by Cushman & Wakefield
  • Home
  • Park Overview
  • Download Brochure